Company
Main
Company Profile
Contact
Product
CF
CFS
MF
MFS
MOF
MOS
Fuse
KNP & NKNP
Resistor Dimensions 
Packing
Color Code
Cement
Cement Dimensions
Power
Chip
Chip Dimensions
NT
Download
Product Catalog




FEATURES CONSTRUCTION POWER CHARACTERISTIC SPECIFICATION
  Cement
      Cement Type Resistor(Wirewound & Metal Oxide Film)

SPECIFICATION

Characteristics Specifications Test methods
DC resistance
(JIS-C-5202 5.1)
J (+5%) Resistance value test at room temperature 25°C
Temperature coefficient
(JIS-C-5202 5.2)
 +350 PPM/°C  
R2-R1   *106 (PPM/°C)
 R1(T2-T1)  
 
R1: Resistance value at room temperature (T1)
R2: Resistance value at room temperature +100°C (T2)
 
 
Load life in humidity
(JIS-C-5202 7.9)
Resistance change rate is
  +(5% +0.05Ω )max. with no evidence of mechanical damage.
Resistance change after 1000Hrs (1.5Hrs on, 0.5Hrs off) At rated voltage in a humidity chamber controlled at 40+2°C and 90-95% relative humidity.
Load life
(JIS-C-5202 7.10)
Resistance change rate is
  +(5% +0.05Ω )max. with no evidence of mechanical damage.
Resistance change after 1000Hrs operating at rated voltage with duty cycle of 1.5Hrs on 0.5Hrs off at
70°C+2°C.
Short time over load
(JIS-C-5202 5.5)
 +(2% +0.05Ω) Resistance change after the application of a potential of 2.5 time rated voltage for 5 seconds.
Electric withstanding voltage
(JIS-C-5202 5.7)
No evidence of flashover mechanical damage,arcing or insulation breakdown. Resistance shall be clamped in the trough of a 90 metallic V-block and shall be test at specified in the above list for 60 seconds.
Pulse overload
(JIS-C-5202 5.8)
Resistance change rate is +(2% + 0.05Ω)max. with no evidence of mechnical damage. Resistance change after 10000 cycles (1 seconds on. 25 seconds off) at 4 time rated voltage(AC)
Temperature cycling
(JIS-C-5202 7.4)
Resistance change rate is +(2%+0.05Ω)Max. with no evidence of mechanical damage. According to the table below for 5 cycles
Step Temperature Time(min)
1  -40°C+3°C 30
2 Room temp. 10-15
3  +155°C+2°C 30
4 Room temp. 10-15
Humidity
(JIS-C-5202 7.4)
Resistance change rate is +(5%+0.05Ω)Max. with no evidence of mechanical damage. Resistance change after 240hrs exposure in a humidity test chamber controlled at 40+2°C and 90-95% relative humidity.
Resistance to soldering heat
(JIS-C-5202 6.4)
Resistance change rate is  +(1%+0.05Ω)Max. with no evidence of mechanical damage. Dipping both side of resistor copper wire 3.2mm to 4.8mm according to the test method below:
Temperature DIP time
350°C+10°C 3.5+0.5sec.
260°C+5°C 10+1.0sec.
Solderability
(JIS-C-5202 6.5)
95% coverage minimum Test temperature of solder: 
235+5°C
Dwell time in solder: 3+0.5 sec.