| Characteristics |
Specifications |
Test methods |
DC
resistance
(JIS-C-5202 5.1) |
J (+5%) |
Resistance value test at room temperature 25°C |
Temperature coefficient
(JIS-C-5202 5.2) |
1/8W |
Less than 4.7Ω |
PPM/°C +350 |
|
|
|
| 1/6W |
4.7Ω - 910Ω |
+300 |
R2-R1 |
*106 (PPM/°C) |
| |
1KΩ - 62KΩ |
+500 |
R1(T2-T1) |
|
| |
68KΩ - 200KΩ |
+700 |
|
|
| |
200KΩ or more |
+1000 |
R1: Resistance value at room temperature (T1) |
| 1/4W |
Less than 4.7Ω |
+350 |
| 1/2W |
4.7Ω - 51KΩ |
+300 |
R2: Resistance value at room temperature +100°C (T2) |
| 1W |
56KΩ - 430KΩ |
+500 |
| 2W |
470KΩ - 910KΩ |
+700 |
|
|
| 3W |
1MΩ or more |
+1000 |
|
|
Load life in humidity
(JIS-C-5202 7.9) |
Resistance change rate, less
than 100K, +3% Max. 100K or more, +5 Max. with no evidence of mechanical
damage. |
Resistance change after 1000Hrs
(1.5Hrs on, 0.5Hrs off) At rated voltage in a humidity chamber controlled at
40+2°C and 90-95% relative
humidity. |
Load life
(JIS-C-5202 7.10) |
Resistance change rate, less
than 56K, +2% Max. 56K or more, +3% Max. with no evidence of mechanical
damage. |
Resistance change after 1000Hrs
operating at rated voltage with duty cycle of 1.5Hrs on 0.5Hrs off at
70°C+2°C. |
Short
time over load
(JIS-C-5202 5.5) |
+(1%+0.05Ω) |
Resistance change after the application of a
potential of 2.5 time rated voltage for 5 seconds. |
Insulation
resistance (JIS-C-5202 5.6) |
10,000Ω or more |
V-Block |
Electric withstanding voltage
(JIS-C-5202 5.7) |
Resistance change rate, |
Resistance shall be clamped in
the trough of a 90 metallic V-block and shall be test at specified in the
above list for 60 seconds. |
| +(0.5% +0.05Ω) |
| no evidence of flashover
mechanical damage,arcing or insulation breakdown. |
Temperature cycling
(JIS-C-5202 7.4) |
Resistance change rate is
+(1%+0.05Ω)Max. with no evidence of mechanical
damage. |
According to the table below for 5 cycles |
| Step |
Temperature |
Time(min) |
| 1 |
-40°C+3°C |
30 |
| 2 |
Room temp. |
10 - 15 |
| 3 |
+155°C+3°C |
30 |
| 4 |
Room temp. |
10 - 15 |
Resistance to soldering heat
(JIS-C-5202 6.4) |
Resistance change rate is
+(1%+0.05Ω)Max. with no evidence
of mechanical damage. |
Dipping both side of resistor copper wire 3.2mm
to 4.8mm according to the test method below: |
| Temperature |
DIP time |
| 350°C+10°C |
3.5+0.5sec. |
| 260°C+5°C |
10+1.0sec. |
Solderability
(JIS-C-5202 6.5) |
95% coverage minimum |
Test
temperature of solder: |
| 235+5°C |
| Dwell time in solder: 3+0.5 sec. |
Resistance
to solvent
(JIS-C-5202 6.9) |
Specimens
shall beimmersed in a bath of tichroethane completelt for 3 mins with
ultrasonic |
No deterioration of protective coating and
marking. |
Terminal strength
(JIS-C-5202 6.1) |
Direct load: Resistance to a
2.5 kgs direct load for 10 seconds in the direction of the longitudinal axis
of the terminal leads. |
No evidence of mechinical
damage. |
| Twist test: Terminal
leads shall be bent 90° a point of about 6 mm. from the body of the resistor
and shall be rotated through 360° about the original axis of the bent
terminal in alternating direction for a total of 3 rotation. |
|
|
|
|
|
|
|
|