| Characteristics |
Specifications |
Test methods |
DC
resistance
(JIS-C-5202 5.1) |
J (+5%) |
Resistance value test at room temperature 25°C |
Temperature coefficient
(JIS-C-5202 5.2) |
+200 PPM/°C |
|
|
|
| R2-R1 |
*106 (PPM/°C) |
| R1(T2-T1) |
|
|
|
| R1: Resistance value at room
temperature (T1) |
| R2: Resistance value at room
temperature +100°C (T2) |
|
|
|
|
Load life in humidity
(JIS-C-5202 7.9) |
Resistance change rate is +(5% +0.05Ω) max. with no evidence of mechanical damage. |
Resistance change after 1000Hrs
(1.5Hrs on, 0.5Hrs off) At rated voltage in a humidity chamber controlled at
40+2°C and 90-95% relative
humidity. |
Load life
(JIS-C-5202 7.10) |
Resistance change rate is +(5% +0.05Ω)max. with no evidence of mechanical damage. |
Resistance change after 1000Hrs
operating at rated voltage with duty cycle of 1.5Hrs on 0.5Hrs off at 70°C+2°C. |
Short time over load
(JIS-C-5202 5.5) |
1/4W 1/2W |
+(2% +0.05Ω) |
Resistance change after the
application of a potential of 2.5 time rated voltage for 5 seconds. |
| 1W 2W |
+(1% +0.05Ω) |
Electric
withstanding voltage
(JIS-C-5202 5.7) |
No evidence of flashover mechanical
damage,arcing or insulation breakdown. |
Resistance shall be clamped in the trough of a
90 metallic V-block and shall be test at specified in the above list for 60
seconds. |
Pulse
overload
(JIS-C-5202 5.8) |
Resistance change rate is +(2% + 0.05Ω)max.
with no evidence of mechnical damage. |
Resistance change after 10000 cycles (1 seconds
on. 25 seconds off) at 4 time rated voltage(AC) |
Temperature cycling
(JIS-C-5202 7.4) |
Resistance change rate is +(2%+0.05Ω)Max. with no evidence of
mechanical damage. |
According to the table below for 5 cycles |
| Step |
Temperature |
Time(min) |
| 1 |
-40°C+3°C |
30 |
| 2 |
Room temp. |
10-15 |
| 3 |
+155°C+2°C |
30 |
| 4 |
Room temp. |
10-15 |
Humidity
(JIS-C-5202 7.4) |
Resistance change rate is +(5%+0.05Ω)Max. with no evidence of mechanical damage. |
Resistance change after 240hrs exposure in a
humidity test chamber controlled at 40+2°C and 90-95%
relative humidity. |
Resistance to soldering heat
(JIS-C-5202 6.4) |
Resistance change rate is +(1%+0.05Ω)Max. with no evidence of mechanical damage. |
Dipping both side of resistor copper wire 3.2mm
to 4.8mm according to the test method below: |
| Temperature |
DIP time |
| 350°C+10°C |
3.5+0.5sec. |
| 260°C+5°C |
10+1.0sec. |
Solderability
(JIS-C-5202 6.5) |
95% coverage minimum |
Test
temperature of solder: |
| 235+5°C |
| Dwell time in solder: 3+0.5 sec. |
| Fusing Characteristic |
Resistance range |
Testing voltage |
With in 60 seconds at testing voltage. |
| 0.1 - 1.0Ω |
32 time of rated voltage. |
| 0.1 -
2.0Ω |
25 time of rated voltage. |
Note: Fusing time shall be
measured as the duration circuit current is decreased to a 1/50 the initial
test current or less. |
| 2.1 -
10.0Ω |
16 time of rated voltage. |
| 10.1 - 1KΩ |
12 time of rated voltage. |
|
|
|
|
|
|
|