| Characteristics |
Specifications |
Test methods |
DC
resistance
(JIS-C-5202 5.1) |
F (+1%)
G (+2%)
J (+5%) |
Resistance value test at room temperature 25°C |
Temperature coefficient
(JIS-C-5202 5.2) |
+200 PPM/°C |
|
|
|
| R2-R1 |
*106 (PPM/°C) |
| R1(T2-T1) |
|
|
|
| R1: Resistance value at room
temperature (T1) |
| R2: Resistance value at room
temperature +100°C (T2) |
|
|
| |
|
|
Load life in humidity
(JIS-C-5202 7.9) |
Resistance change rate is +(5% +0.05Ω) max. with no evidence of mechanical damage. |
Resistance change after 1000Hrs
(1.5Hrs on, 0.5Hrs off) At rated voltage in a humidity chamber controlled at
40+2°C and 90-95% relative
humidity. |
Load life
(JIS-C-5202 7.10) |
Resistance change rate is +(5% +0.05Ω)max. with no evidence of mechanical damage. |
Resistance change after 1000Hrs
operating at rated voltage with duty cycle of 1.5Hrs on 0.5Hrs off at
70°C+2°C. |
Short time over load
(JIS-C-5202 5.5) |
+(1% +0.05Ω) |
Resistance change after the
application of a potential of 2.5 time rated voltage for 5 seconds. |
Insulation
resistance (JIS-C-5202 5.6) |
1000MΩ or more |
V-Block |
Resistance to soldering heat
(JIS-C-5202 6.4) |
Resistance change rate is +(1%+0.05Ω)Max. with no evidence of mechanical damage. |
Dipping both side of resistor copper wire 3.2mm
to 4.8mm according to the test method below: |
| Temperature |
DIP time |
| 350°C+10°C |
3.5+0.5sec. |
| 260°C+5°C |
10+1.0sec. |
Solderability
(JIS-C-5202 6.5) |
95% coverage minimum |
Test
temperature of solder: |
| 235+5°C |
| Dwell time in solder: 3+0.5 sec. |
|
|
|
|
|
|
|